inflated object count causes TestCommand_getFromBuffer to read one byte
past the end of the heap-allocated message buffer.
No advisories yet.
Solution
MZ Automation recommends users update to version 2.4.1 when available. See MZ Automation advisory for more information: https://github.com/mz-automation/lib60870/security/advisories/GHSA-g3w7-x5rx-83xm
Workaround
No workaround given by the vendor.
Fri, 31 Jul 2026 00:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Mz-automation
Mz-automation lib60870 |
|
| Vendors & Products |
Mz-automation
Mz-automation lib60870 |
Thu, 30 Jul 2026 23:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A crafted IEC 60870-5-104 I-frame with TypeID 104 (C_TS_NA_1) and an inflated object count causes TestCommand_getFromBuffer to read one byte past the end of the heap-allocated message buffer. | |
| Title | MZ Automation lib60870 Out-of-bounds Read | |
| Weaknesses | CWE-125 | |
| References |
| |
| Metrics |
cvssV3_1
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2026-07-30T22:58:32.226Z
Reserved: 2026-07-16T22:10:53.022Z
Link: CVE-2026-61893
No data.
No data.
No data.
OpenCVE Enrichment
Updated: 2026-07-31T00:30:18Z