No advisories yet.
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
Mon, 20 Jul 2026 23:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Openplcproject
Openplcproject openplc V3 |
|
| Vendors & Products |
Openplcproject
Openplcproject openplc V3 |
Mon, 20 Jul 2026 18:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
Sat, 18 Jul 2026 14:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | OpenPLC_v3 contains a heap-based buffer overflow in the getData() function in webserver/core/modbus_master.cpp. getData() reads characters between two delimiters into a caller-supplied buffer with no size parameter and no bounds check. In parseConfig() the function is invoked with the 100-byte heap-allocated MB_device.dev_name field. An authenticated attacker with access to the OpenPLC web interface can send a crafted HTTP POST to the /modbus endpoint with an oversized device_name value; the value is persisted to mbconfig.cfg and parsed on load, overflowing dev_name and overwriting adjacent struct fields (protocol at offset 108, dev_address at offset 109, ip_port at offset 210). A 200-byte payload writes 100 bytes past the allocation. The result is heap corruption leading to runtime crash and denial of service of the PLC process control loop, with attacker-controlled overwrite of adjacent configuration fields. The upstream repository was archived on 2026-04-04 and no fix is expected; the vendor has confirmed the issue does not affect OpenPLC Runtime v4. | |
| Title | OpenPLC_v3 Heap-Based Buffer Overflow in Modbus Master getData() | |
| Weaknesses | CWE-122 | |
| References |
|
|
| Metrics |
cvssV3_1
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: VulnCheck
Published:
Updated: 2026-07-20T17:45:50.286Z
Reserved: 2026-06-09T19:53:45.722Z
Link: CVE-2026-11826
Updated: 2026-07-20T17:02:06.021Z
No data.
No data.
OpenCVE Enrichment
Updated: 2026-07-20T23:30:03Z