Export limit exceeded: 339475 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 339475 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 339475 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 20907 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (20907 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-26365 1 Amd 108 Amd 3015ce, Amd 3015ce Firmware, Amd 3015e and 105 more 2025-01-28 8.2 High
Certain size values in firmware binary headers could trigger out of bounds reads during signature validation, leading to denial of service or potentially limited leakage of information about out-of-bounds memory contents.
CVE-2021-26354 1 Amd 304 Amd 3015ce, Amd 3015ce Firmware, Amd 3015e and 301 more 2025-01-28 5.5 Medium
Insufficient bounds checking in ASP may allow an attacker to issue a system call from a compromised ABL which may cause arbitrary memory values to be initialized to zero, potentially leading to a loss of integrity.
CVE-2024-0146 2025-01-28 7.8 High
NVIDIA vGPU software contains a vulnerability in the Virtual GPU Manager, where a malicious guest could cause memory corruption. A successful exploit of this vulnerability might lead to code execution, denial of service, information disclosure, or data tampering.
CVE-2022-36330 1 Westerndigital 6 My Cloud Home, My Cloud Home Duo, My Cloud Home Duo Firmware and 3 more 2025-01-28 1.9 Low
A buffer overflow vulnerability was discovered on firmware version validation that could lead to an unauthenticated remote code execution in Western Digital My Cloud Home, My Cloud Home Duo and SanDisk ibi devices. An attacker would require exploitation of another vulnerability to raise their privileges in order to exploit this buffer overflow vulnerability. This issue affects My Cloud Home and My Cloud Home Duo: before 9.4.0-191; ibi: before 9.4.0-191. 
CVE-2023-2629 1 Pimcore 1 Customer Management Framework 2025-01-27 7.8 High
Improper Neutralization of Formula Elements in a CSV File in GitHub repository pimcore/customer-data-framework prior to 3.3.9.
CVE-2023-43538 1 Qualcomm 274 Aqt1000, Aqt1000 Firmware, Ar8035 and 271 more 2025-01-27 9.3 Critical
Memory corruption in TZ Secure OS while Tunnel Invoke Manager initialization.
CVE-2024-4491 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4492 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4493 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4494 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4495 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4496 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4237 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4238 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4239 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4240 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4241 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4242 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4243 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4244 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.