Export limit exceeded: 42196 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (42196 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2020-7641 | 1 Grunt-util-property Project | 1 Grunt-util-property | 2024-11-21 | 4 Medium |
| This affects all versions of package grunt-util-property. The function call could be tricked into adding or modifying properties of Object.prototype using a __proto__ payload. | ||||
| CVE-2020-7639 | 1 Dot Project | 1 Dot | 2024-11-21 | 5.3 Medium |
| eivindfjeldstad-dot below 1.0.3 is vulnerable to Prototype Pollution.The function 'set' could be tricked into adding or modifying properties of 'Object.prototype' using a '__proto__' payload. | ||||
| CVE-2020-7638 | 1 Confinit Project | 1 Confinit | 2024-11-21 | 5.3 Medium |
| confinit through 0.3.0 is vulnerable to Prototype Pollution.The 'setDeepProperty' function could be tricked into adding or modifying properties of 'Object.prototype' using a '__proto__' payload. | ||||
| CVE-2020-7637 | 1 Class-transformer Project | 1 Class-transformer | 2024-11-21 | 5.3 Medium |
| class-transformer before 0.3.1 allow attackers to perform Prototype Pollution. The classToPlainFromExist function could be tricked into adding or modifying properties of Object.prototype using a __proto__ payload. | ||||
| CVE-2020-7618 | 1 Sds Project | 1 Sds | 2024-11-21 | 5.3 Medium |
| sds through 3.2.0 is vulnerable to Prototype Pollution.The library could be tricked into adding or modifying properties of the 'Object.prototype' by abusing the 'set' function located in 'js/set.js'. | ||||
| CVE-2020-7617 | 1 Ini-parser Project | 1 Ini-parser | 2024-11-21 | 4.4 Medium |
| ini-parser through 0.0.2 is vulnerable to Prototype Pollution.The library could be tricked into adding or modifying properties of Object.prototype using a '__proto__' payload. | ||||
| CVE-2020-7616 | 1 Express-mock-middleware Project | 1 Express-mock-middleware | 2024-11-21 | 5.3 Medium |
| express-mock-middleware through 0.0.6 is vulnerable to Prototype Pollution. Exported functions by the package can be tricked into adding or modifying properties of the `Object.prototype`. Exploitation of this vulnerability requires creation of a new directory where an attack code can be placed which will then be exported by `express-mock-middleware`. As such, this is considered to be a low risk. | ||||
| CVE-2020-7608 | 2 Redhat, Yargs | 5 Enterprise Linux, Openshift Container Storage, Quay and 2 more | 2024-11-21 | 5.3 Medium |
| yargs-parser could be tricked into adding or modifying properties of Object.prototype using a "__proto__" payload. | ||||
| CVE-2020-7600 | 1 Querymen Project | 1 Querymen | 2024-11-21 | 5.3 Medium |
| querymen prior to 2.1.4 allows modification of object properties. The parameters of exported function handler(type, name, fn) can be controlled by users without any sanitization. This could be abused for Prototype Pollution attacks. | ||||
| CVE-2020-7598 | 3 Opensuse, Redhat, Substack | 9 Leap, Enterprise Linux, Openshift and 6 more | 2024-11-21 | 5.6 Medium |
| minimist before 1.2.2 could be tricked into adding or modifying properties of Object.prototype using a "constructor" or "__proto__" payload. | ||||
| CVE-2020-7593 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2024-11-21 | 9.8 Critical |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (V1.81.01 - V1.81.03), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.01), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.02). A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacker could send a specially crafted HTTP request to cause a memory corruption, potentially resulting in remote code execution. | ||||
| CVE-2020-7586 | 1 Siemens | 4 Simatic Pcs 7, Simatic Process Device Manager, Simatic Step 7 and 1 more | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information. | ||||
| CVE-2020-7564 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2024-11-21 | 8.8 High |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2020-7562 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2024-11-21 | 8.1 High |
| A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2020-7560 | 1 Schneider-electric | 2 Ecostruxure Control Expert, Unity Pro | 2024-11-21 | 8.6 High |
| A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. | ||||
| CVE-2020-7559 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | 7.5 High |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. | ||||
| CVE-2020-7557 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
| CVE-2020-7554 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
| CVE-2020-7550 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
| CVE-2020-7512 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2024-11-21 | 9.8 Critical |
| A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component. | ||||