Export limit exceeded: 21088 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (21088 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-20161 2026-04-15 5.1 Medium
A vulnerability in the software upgrade process of Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an authenticated, local attacker with valid Administrator credentials to execute a command injection attack on the underlying operating system of an affected device. This vulnerability is due to insufficient validation of specific elements within a software image. An attacker could exploit this vulnerability by installing a crafted image. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with root privileges.  Note: Administrators should validate the hash of any software image before installation.
CVE-2025-8667 1 Skyworkai 1 Deepresearchagent 2026-04-15 6.3 Medium
A vulnerability, which was classified as critical, was found in SkyworkAI DeepResearchAgent up to 08eb7f8eb9505d0094d75bb97ff7dacc3fa3bbf2. Affected is the function from_code/from_dict/from_mcp of the file src/tools/tools.py. The manipulation leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-9494 1 Viessmann 1 Vitogate 300 2026-04-15 N/A
An OS command injection vulnerability has been discovered in the Vitogate 300, which can be exploited by malicious users to compromise affected installations. Specifically, the `/cgi-bin/vitogate.cgi` endpoint is affected, when the `form` JSON parameter is set to `form-0-2`. The vulnerability stems from the fact that that function at offset 0x21c24 does not properly sanitize supplied input before interpolating it into a format string which gets passed to `popen()`. Consequently, an authenticated attacker is able to inject arbitrary OS commands and thus gain code execution on affected devices.
CVE-2025-59730 1 Ffmpeg 1 Ffmpeg 2026-04-15 6.5 Medium
When decoding a frame for a SANM file (ANIM v0 variant), the decoded data can be larger than the buffer allocated for it. Frames encoded with codec 48 can specify their resolution (width x height). A buffer of appropriate size is allocated depending on the resolution. This codec can encode the frame contents using a run-length encoding algorithm. There are no checks that the decoded frame fits in the allocated buffer, leading to a heap-buffer-overflow. process_frame_obj initializes the buffers based on the frame resolution: We recommend upgrading to version 8.0 or beyond.
CVE-2025-4640 2026-04-15 N/A
Out-of-bounds Write vulnerability in PointCloudLibrary pcl allows Overflow Buffers. Since version 1.14.0, PCL by default uses a zlib installation from the system, unless the user sets WITH_SYSTEM_ZLIB=FALSE. So this potential vulnerability is only relevant if the PCL version is older than 1.14.0 or the user specifically requests to not use the system zlib.
CVE-2025-46334 2026-04-15 8.6 High
Git GUI allows you to use the Git source control management tools via a GUI. A malicious repository can ship versions of sh.exe or typical textconv filter programs such as astextplain. Due to the unfortunate design of Tcl on Windows, the search path when looking for an executable always includes the current directory. The mentioned programs are invoked when the user selects Git Bash or Browse Files from the menu. This vulnerability is fixed in 2.43.7, 2.44.4, 2.45.4, 2.46.4, 2.47.3, 2.48.2, 2.49.1, and 2.50.1.
CVE-2025-20014 1 Myscada 1 Mypro Manager 2026-04-15 9.8 Critical
mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system.
CVE-2025-20016 2026-04-15 7.2 High
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340/D440 provided by Y'S corporation. A user with an administrative privilege who logged in to the web management page of the affected product may execute an arbitrary OS command.
CVE-2025-47203 1 Dropbear Ssh Project 1 Dropbear Ssh 2026-04-15 4.5 Medium
dbclient in Dropbear SSH before 2025.88 allows command injection via an untrusted hostname argument, because a shell is used.
CVE-2025-27614 2026-04-15 8.6 High
Gitk is a Tcl/Tk based Git history browser. Starting with 2.41.0, a Git repository can be crafted in such a way that with some social engineering a user who has cloned the repository can be tricked into running any script (e.g., Bourne shell, Perl, Python, ...) supplied by the attacker by invoking gitk filename, where filename has a particular structure. The script is run with the privileges of the user. This vulnerability is fixed in 2.43.7, 2.44.4, 2.45.4, 2.46.4, 2.47.3, 2.48.2, 2.49.1, and 2.50.
CVE-2024-53992 1 Emd115 1 Unzip Bot 2026-04-15 N/A
unzip-bot is a Telegram bot to extract various types of archives. Users could exploit unsanitized inputs to inject malicious commands that are executed through subprocess.Popen with shell=True. Attackers can exploit this vulnerability using a crafted archive name, password, or video name. This vulnerability is fixed in 7.0.3a.
CVE-2025-2733 1 Mannaandpoem 1 Openmanus 2026-04-15 6.3 Medium
A vulnerability classified as critical has been found in mannaandpoem OpenManus up to 2025.3.13. This affects an unknown part of the file app/tool/python_execute.py of the component Prompt Handler. The manipulation leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-12052 1 Insyde 1 Insydeh2o 2026-04-15 7.8 High
The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow.
CVE-2025-12050 1 Insyde 1 Insydeh2o 2026-04-15 7.8 High
The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow.
CVE-2013-10049 2026-04-15 N/A
An OS command injection vulnerability exists in multiple Raidsonic NAS devices—specifically tested on IB-NAS5220 and IB-NAS4220—via the unauthenticated timeHandler.cgi endpoint exposed through the web interface. The CGI script fails to properly sanitize user-supplied input in the timeZone parameter of a POST request, allowing remote attackers to inject arbitrary shell commands.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-6183 2 Apple, Strongdm 2 Macos, Sdm-cli 2026-04-15 N/A
The StrongDM macOS client incorrectly processed JSON-formatted messages. Attackers could potentially modify macOS system configuration by crafting a malicious JSON message.
CVE-2025-48499 1 Fujifilm 8 Apeos 2150, Apeos 2350, Docuprint M115 W and 5 more 2026-04-15 5.3 Medium
Out-of-bounds write vulnerability exists in FUJIFILM Business Innovation MFPs. A specially crafted IPP (Internet Printing Protocol) or LPD (Line Printer Daemon) packet may cause a denial-of-service (DoS) condition on an affected MFP. Resetting the MFP is required to recover from the denial-of-service (DoS) condition.
CVE-2025-10589 1 N-partner 3 N-cloud, N-probe, N-reporter 2026-04-15 8.8 High
The N-Reporter, N-Cloud, and N-Probe developed by N-Partner has an OS Command Injection vulnerability, allowing authenticated remote attackers to inject arbitrary OS commands and execute them on the server.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).