Search Results (425 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-58115 1 Siemens 1 Simatic Iot2050 2026-08-13 10 Critical
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
CVE-2023-44487 33 Akka, Amazon, Apache and 30 more 378 Http Server, Opensearch Data Prepper, Apisix and 375 more 2026-08-11 7.5 High
The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.
CVE-2021-42554 2 Insyde, Siemens 31 Insydeh2o, Ruggedcom Ape1808, Ruggedcom Ape1808 Firmware and 28 more 2026-08-11 8.2 High
An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
CVE-2021-42059 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2026-08-11 6.7 Medium
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
CVE-2021-41838 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2026-08-11 8.2 High
An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
CVE-2021-41837 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2026-08-11 8.2 High
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
CVE-2021-33627 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2026-08-11 8.2 High
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
CVE-2021-33626 2 Insyde, Siemens 33 Insydeh2o, Ruggedcom Apr1808, Ruggedcom Apr1808 Firmware and 30 more 2026-08-11 7.8 High
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
CVE-2021-33625 3 Insyde, Netapp, Siemens 34 Insydeh2o, Fas\/aff Bios, Ruggedcom Ape1808 and 31 more 2026-08-11 7.5 High
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
CVE-2020-5953 2 Insyde, Siemens 33 Insydeh2o, Ruggedcom Ape1808, Ruggedcom Ape1808 Firmware and 30 more 2026-08-11 7.5 High
A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2).
CVE-2020-27339 2 Insyde, Siemens 33 Insydeh2o, Ruggedcom Apr1808, Ruggedcom Apr1808 Firmware and 30 more 2026-08-11 6.7 Medium
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).
CVE-2024-49894 3 Debian, Linux, Siemens 5 Debian Linux, Linux Kernel, Simatic S7-1500 Tm Mfp and 2 more 2026-08-04 7.1 High
In the Linux kernel, the following vulnerability has been resolved: drm/amd/display: Fix index out of bounds in degamma hardware format translation Fixes index out of bounds issue in `cm_helper_translate_curve_to_degamma_hw_format` function. The issue could occur when the index 'i' exceeds the number of transfer function points (TRANSFER_FUNC_POINTS). The fix adds a check to ensure 'i' is within bounds before accessing the transfer function points. If 'i' is out of bounds the function returns false to indicate an error. Reported by smatch: drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:594 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.red' 1025 <= s32max drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:595 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.green' 1025 <= s32max drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:596 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.blue' 1025 <= s32max
CVE-2026-54429 1 Siemens 1 Simatic S7-plcsim Advanced 2026-07-31 7.4 High
A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance.
CVE-2025-38502 3 Debian, Linux, Siemens 4 Debian Linux, Linux Kernel, Simatic Cn 4100 and 1 more 2026-07-30 7.8 High
In the Linux kernel, the following vulnerability has been resolved: bpf: Fix oob access in cgroup local storage Lonial reported that an out-of-bounds access in cgroup local storage can be crafted via tail calls. Given two programs each utilizing a cgroup local storage with a different value size, and one program doing a tail call into the other. The verifier will validate each of the indivial programs just fine. However, in the runtime context the bpf_cg_run_ctx holds an bpf_prog_array_item which contains the BPF program as well as any cgroup local storage flavor the program uses. Helpers such as bpf_get_local_storage() pick this up from the runtime context: ctx = container_of(current->bpf_ctx, struct bpf_cg_run_ctx, run_ctx); storage = ctx->prog_item->cgroup_storage[stype]; if (stype == BPF_CGROUP_STORAGE_SHARED) ptr = &READ_ONCE(storage->buf)->data[0]; else ptr = this_cpu_ptr(storage->percpu_buf); For the second program which was called from the originally attached one, this means bpf_get_local_storage() will pick up the former program's map, not its own. With mismatching sizes, this can result in an unintended out-of-bounds access. To fix this issue, we need to extend bpf_map_owner with an array of storage_cookie[] to match on i) the exact maps from the original program if the second program was using bpf_get_local_storage(), or ii) allow the tail call combination if the second program was not using any of the cgroup local storage maps.
CVE-2026-24349 1 Siemens 1 Simatic Wincc Unified Pc Runtime 2026-06-09 7.1 High
A vulnerability has been identified in SIMATIC WinCC Unified PC Runtime V16 (All versions), SIMATIC WinCC Unified PC Runtime V17 (All versions), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions), SIMATIC WinCC Unified PC Runtime V20 (All versions), SIMATIC WinCC Unified PC Runtime V21 (All versions < V21 Update 2). Insufficient protection of key material in WinCC Certificate Manager that could allow an attacker to extract sensitive information.
CVE-2025-40944 1 Siemens 15 Simatic Et 200al Im 157-1 Pn, Simatic Et 200mp Im 155-5 Pn Hf, Simatic Et 200sp Im 155-6 Mf Hf and 12 more 2026-06-09 7.5 High
A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (All versions < V1.3), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (All versions < V6.0.1), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (All versions >= V4.2.0 < V4.2.5), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (All versions < V4.2.2), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (All versions), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (All versions < V6.0.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (All versions >= V4.2.0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (All versions < V6.0.0). Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state. This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation.
CVE-2025-40798 1 Siemens 3 Simatic, Simatic Pcs Neo, User Management Component 2026-06-09 7.5 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
CVE-2025-40797 1 Siemens 3 Simatic, Simatic Pcs Neo, User Management Component 2026-06-09 7.5 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
CVE-2025-40796 1 Siemens 3 Simatic, Simatic Pcs Neo, User Management Component 2026-06-09 7.5 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
CVE-2025-40795 1 Siemens 3 Simatic, Simatic Pcs Neo, User Management Component 2026-06-09 9.8 Critical
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition.