Search Results (2302 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-36061 1 Elrond 1 Elrond Go 2025-04-22 6.5 Medium
Elrond go is the go implementation for the Elrond Network protocol. In versions prior to 1.3.35, read only calls between contracts can generate smart contracts results. For example, if contract A calls in read only mode contract B and the called function will make changes upon the contract's B state, the state will be altered for contract B as if the call was not made in the read-only mode. This can lead to some effects not designed by the original smart contracts programmers. This issue was patched in version 1.3.35. There are no known workarounds.
CVE-2022-39284 1 Codeigniter 1 Codeigniter 2025-04-22 2.6 Low
CodeIgniter is a PHP full-stack web framework. In versions prior to 4.2.7 setting `$secure` or `$httponly` value to `true` in `Config\Cookie` is not reflected in `set_cookie()` or `Response::setCookie()`. As a result cookie values are erroneously exposed to scripts. It should be noted that this vulnerability does not affect session cookies. Users are advised to upgrade to v4.2.7 or later. Users unable to upgrade are advised to manually construct their cookies either by setting the options in code or by constructing Cookie objects. Examples of each workaround are available in the linked GHSA.
CVE-2022-20566 1 Google 1 Android 2025-04-21 7.8 High
In l2cap_chan_put of l2cap_core, there is a possible use after free due to improper locking. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-165329981References: Upstream kernel
CVE-2021-22572 1 Google 1 Data Transfer Project 2025-04-21 5.5 Medium
On unix-like systems, the system temporary directory is shared between all users on that system. The root cause is File.createTempFile creates files in the the system temporary directory with world readable permissions. Any sensitive information written to theses files is visible to all other local users on unix-like systems. We recommend upgrading past commit https://github.com/google/data-transfer-project/pull/969
CVE-2022-46144 1 Siemens 12 6gk5622-2gs00-2ac2, 6gk5622-2gs00-2ac2 Firmware, 6gk5626-2gs00-2ac2 and 9 more 2025-04-21 6.5 Medium
A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.
CVE-2017-13649 1 Unrealircd 1 Unrealircd 2025-04-20 N/A
UnrealIRCd 4.0.13 and earlier creates a PID file after dropping privileges to a non-root account, which might allow local users to kill arbitrary processes by leveraging access to this non-root account for PID file modification before a root script executes a "kill `cat /pathname`" command. NOTE: the vendor indicates that there is no common or recommended scenario in which a root script would execute this kill command.
CVE-2017-14159 2 Openldap, Oracle 2 Openldap, Blockchain Platform 2025-04-20 4.7 Medium
slapd in OpenLDAP 2.4.45 and earlier creates a PID file after dropping privileges to a non-root account, which might allow local users to kill arbitrary processes by leveraging access to this non-root account for PID file modification before a root script executes a "kill `cat /pathname`" command, as demonstrated by openldap-initscript.
CVE-2014-9942 1 Google 1 Android 2025-04-20 N/A
In Boot in all Android releases from CAF using the Linux kernel, a Use of Uninitialized Variable vulnerability could potentially exist.
CVE-2017-12262 1 Cisco 1 Application Policy Infrastructure Controller Enterprise Module 2025-04-20 N/A
A vulnerability within the firewall configuration of the Cisco Application Policy Infrastructure Controller Enterprise Module (APIC-EM) could allow an unauthenticated, adjacent attacker to gain privileged access to services only available on the internal network of the device. The vulnerability is due to an incorrect firewall rule on the device. The misconfiguration could allow traffic sent to the public interface of the device to be forwarded to the internal virtual network of the APIC-EM. An attacker that is logically adjacent to the network on which the public interface of the affected APIC-EM resides could leverage this behavior to gain access to services listening on the internal network with elevated privileges. This vulnerability affects appliances or virtual devices running Cisco Application Policy Infrastructure Controller Enterprise Module prior to version 1.5. Cisco Bug IDs: CSCve89638.
CVE-2017-17087 3 Canonical, Debian, Vim 3 Ubuntu Linux, Debian Linux, Vim 2025-04-20 5.5 Medium
fileio.c in Vim prior to 8.0.1263 sets the group ownership of a .swp file to the editor's primary group (which may be different from the group ownership of the original file), which allows local users to obtain sensitive information by leveraging an applicable group membership, as demonstrated by /etc/shadow owned by root:shadow mode 0640, but /etc/.shadow.swp owned by root:users mode 0640, a different vulnerability than CVE-2017-1000382.
CVE-2017-8171 1 Huawei 2 P10 Plus, P10 Plus Firmware 2025-04-20 N/A
Huawei smart phones with software earlier than Vicky-AL00AC00B172D versions have a Factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the Talkback mode and can perform some operations to bypass the Google account verification. As a result, the FRP function is bypassed.
CVE-2017-8161 1 Huawei 1 Eva-l09 2025-04-20 N/A
EVA-L09 smartphones with software Earlier than EVA-L09C25B150CUSTC25D003 versions,Earlier than EVA-L09C440B140 versions,Earlier than EVA-L09C464B361 versions,Earlier than EVA-L09C675B320CUSTC675D004 versions have Factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the Swype and can perform some operations to update the Google account. As a result, the FRP function is bypassed.
CVE-2017-3820 1 Cisco 1 Ios Xe 2025-04-20 N/A
A vulnerability in Simple Network Management Protocol (SNMP) functions of Cisco ASR 1000 Series Aggregation Services Routers running Cisco IOS XE Software Release 3.13.6S, 3.16.2S, or 3.17.1S could allow an authenticated, remote attacker to cause high CPU usage on an affected device, resulting in a denial of service (DoS) condition. More Information: CSCux68796. Known Affected Releases: 15.5(3)S2.1 15.6(1)S1.1. Known Fixed Releases: 15.4(3)S6.1 15.4(3)S6.2 15.5(3)S2.2 15.5(3)S3 15.6(0.22)S0.23 15.6(1)S2 16.2(0.295) 16.3(0.94) 15.5.3S3.
CVE-2017-6267 2 Microsoft, Nvidia 2 Windows, Gpu Driver 2025-04-20 N/A
NVIDIA GPU Display Driver contains a vulnerability in the kernel mode layer handler where an incorrect initialization of internal objects can cause an infinite loop which may lead to a denial of service.
CVE-2017-7490 1 Moodle 1 Moodle 2025-04-20 N/A
In Moodle 2.x and 3.x, searching of arbitrary blogs is possible because a capability check is missing.
CVE-2017-0215 1 Microsoft 2 Windows 10, Windows Server 2016 2025-04-20 N/A
Microsoft Windows 10 1607 and Windows Server 2016 allow an attacker to exploit a security feature bypass vulnerability in Device Guard that could allow the attacker to inject malicious code into a Windows PowerShell session, aka "Device Guard Code Integrity Policy Security Feature Bypass Vulnerability." This CVE ID is unique from CVE-2017-0173, CVE-2017-0216, CVE-2017-0218, and CVE-2017-0219.
CVE-2016-10229 2 Google, Linux 2 Android, Linux Kernel 2025-04-20 9.8 Critical
udp.c in the Linux kernel before 4.5 allows remote attackers to execute arbitrary code via UDP traffic that triggers an unsafe second checksum calculation during execution of a recv system call with the MSG_PEEK flag.
CVE-2017-12342 1 Cisco 1 Nx-os 2025-04-20 N/A
A vulnerability in the Open Agent Container (OAC) feature of Cisco Nexus Series Switches could allow an unauthenticated, local attacker to read and send packets outside the scope of the OAC. The vulnerability is due to insufficient internal security measures in the OAC feature. An attacker could exploit this vulnerability by crafting specific packets for communication on the device-internal network. A successful exploit could allow the attacker to run code on the underlying host operating system. OAC is not enabled by default. For a device to be vulnerable, an administrator would need to install and activate this feature. This vulnerability affects the following Cisco Nexus Series Switches: Nexus 2000 Series Fabric Extenders, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches. Cisco Bug IDs: CSCve53542, CSCvf36621.
CVE-2016-8368 1 Mitsubishielectric 6 Qj71e71-100, Qj71e71-100 Firmware, Qj71e71-b2 and 3 more 2025-04-20 8.6 High
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.
CVE-2017-14681 1 P3scan Project 1 P3scan 2025-04-20 N/A
The daemon in P3Scan 3.0_rc1 and earlier creates a p3scan.pid file after dropping privileges to a non-root account, which might allow local users to kill arbitrary processes by leveraging access to this non-root account for p3scan.pid modification before a root script executes a "kill `cat /pathname/p3scan.pid`" command, as demonstrated by etc/init.d/p3scan.