Export limit exceeded: 339475 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (19553 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-30522 4 Apache, Fedoraproject, Netapp and 1 more 6 Http Server, Fedora, Clustered Data Ontap and 3 more 2024-11-21 7.5 High
If Apache HTTP Server 2.4.53 is configured to do transformations with mod_sed in contexts where the input to mod_sed may be very large, mod_sed may make excessively large memory allocations and trigger an abort.
CVE-2022-30521 1 Dlink 2 Dir-890l, Dir-890l Firmware 2024-11-21 9.8 Critical
The LAN-side Web-Configuration Interface has Stack-based Buffer Overflow vulnerability in the D-Link Wi-Fi router firmware DIR-890L DIR890LA1_FW107b09.bin and previous versions. The function created at 0x17958 of /htdocs/cgibin will call sprintf without checking the length of strings in parameters given by HTTP header and can be controlled by users easily. The attackers can exploit the vulnerability to carry out arbitrary code by means of sending a specially constructed payload to port 49152.
CVE-2022-30477 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 9.8 Critical
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request.
CVE-2022-30476 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 9.8 Critical
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request.
CVE-2022-30475 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 7.5 High
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request.
CVE-2022-30474 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 9.8 Critical
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request.
CVE-2022-30473 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 7.5 High
Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set
CVE-2022-30472 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 9.8 Critical
Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat
CVE-2022-30425 1 Tenda 2 Hg6, Hg6 Firmware 2024-11-21 8.8 High
Tenda Technology Co.,Ltd HG6 3.3.0-210926 was discovered to contain a command injection vulnerability via the pingAddr and traceAddr parameters. This vulnerability is exploited via a crafted POST request.
CVE-2022-30329 1 Trendnet 2 Tew-831dr, Tew-831dr Firmware 2024-11-21 9.8 Critical
An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. An OS injection vulnerability exists within the web interface, allowing an attacker with valid credentials to execute arbitrary shell commands.
CVE-2022-30311 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30310 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30309 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30308 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30306 1 Fortinet 1 Fortiweb 2024-11-21 6.3 Medium
A stack-based buffer overflow vulnerability [CWE-121] in the CA sign functionality of FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below may allow an authenticated attacker to achieve arbitrary code execution via specifically crafted password.
CVE-2022-30303 1 Fortinet 1 Fortiweb 2024-11-21 8.6 High
An improper neutralization of special elements used in an os command ('OS Command Injection') [CWE-78] in FortiWeb 7.0.0 through 7.0.1, 6.3.0 through 6.3.19, 6.4 all versions may allow an authenticated attacker to execute arbitrary shell code as `root` user via crafted HTTP requests.
CVE-2022-30293 3 Debian, Redhat, Webkitgtk 4 Debian Linux, Enterprise Linux, Rhel Els and 1 more 2024-11-21 7.5 High
In WebKitGTK through 2.36.0 (and WPE WebKit), there is a heap-based buffer overflow in WebCore::TextureMapperLayer::setContentsLayer in WebCore/platform/graphics/texmap/TextureMapperLayer.cpp.
CVE-2022-30292 2 Fedoraproject, Squirrel-lang 2 Fedora, Squirrel 2024-11-21 10.0 Critical
Heap-based buffer overflow in sqbaselib.cpp in SQUIRREL 3.2 due to lack of a certain sq_reservestack call.
CVE-2022-30105 1 Belkin 2 N300, N300 Firmware 2024-11-21 9.8 Critical
In Belkin N300 Firmware 1.00.08, the script located at /setting_hidden.asp, which is accessible before and after configuring the device, exhibits multiple remote command injection vulnerabilities. The following parameters in the [form name] form; [list vulnerable parameters], are not properly sanitized after being submitted to the web interface in a POST request. With specially crafted parameters, it is possible to inject a an OS command which will be executed with root privileges, as the web interface, and all processes on the device, run as root.
CVE-2022-30079 1 Netgear 1 R6200 2024-11-21 8.8 High
Command injection vulnerability was discovered in Netgear R6200 v2 firmware through R6200v2-V1.0.3.12 via binary /sbin/acos_service that could allow remote authenticated attackers the ability to modify values in the vulnerable parameter.