Search Results (324 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2018-25169 2 Ampps, Softaculous 2 Ampps, Ampps 2026-04-15 7.5 High
AMPPS 2.7 contains a denial of service vulnerability that allows remote attackers to crash the service by sending malformed data to the default HTTP port. Attackers can establish multiple socket connections and transmit invalid payloads to exhaust server resources and cause service unavailability.
CVE-2025-14758 1 Alasca 1 Yaook 2026-04-15 6.5 Medium
Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2024-28815 1 Mitel 2 Cmg Suite, Inattend 2026-04-15 9.8 Critical
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
CVE-2024-25972 1 Atsumi 1 Oet-213h-bts1 2026-04-15 8.3 High
Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product.
CVE-2025-2442 2026-04-15 6.8 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.
CVE-2024-34063 2026-04-15 2.5 Low
vodozemac is an implementation of Olm and Megolm in pure Rust. Versions 0.5.0 and 0.5.1 of vodozemac have degraded secret zeroization capabilities, due to changes in third-party cryptographic dependencies (the Dalek crates), which moved secret zeroization capabilities behind a feature flag and defaulted this feature to off. The degraded zeroization capabilities could result in the production of more memory copies of encryption secrets and secrets could linger in memory longer than necessary. This marginally increases the risk of sensitive data exposure. This issue has been addressed in version 0.6.0 and users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-48122 2026-04-15 6.7 Medium
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges.
CVE-2019-25219 1 Asio 1 Cplusplus Library 2026-04-15 7.5 High
Asio C++ Library before 1.13.0 lacks a fallback error code in the case of SSL_ERROR_SYSCALL with no associated error information from the SSL library being used.
CVE-2025-41713 1 Wago 1 Cc100 2026-04-15 6.5 Medium
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
CVE-2025-41672 1 Wago 1 Device Sphere 2026-04-15 10 Critical
A remote unauthenticated attacker may use default certificates to generate JWT Tokens and gain full access to the tool and all connected devices.
CVE-2025-41438 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
CVE-2025-24288 1 Versa 1 Director 2026-04-15 9.8 Critical
The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2025-61481 1 Mikrotik 2 Routeros, Switchos 2026-04-15 10 Critical
An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials.
CVE-2025-52622 1 Hcltech 1 Bigfix Saas 2026-04-15 5.4 Medium
The BigFix SaaS's HTTP responses were missing some security headers. The absence of these headers weakens the application's client-side security posture, making it more vulnerable to common web attacks that these headers are designed to mitigate, such as Cross-Site Scripting (XSS), Clickjacking, and protocol downgrade attacks.
CVE-2025-59090 1 Dormakaba 1 Kaba Exos 9300 2026-04-15 N/A
On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards.
CVE-2024-2912 1 Bentoml 1 Bentoml 2026-04-15 10 Critical
An insecure deserialization vulnerability exists in the BentoML framework, allowing remote code execution (RCE) by sending a specially crafted POST request. By exploiting this vulnerability, attackers can execute arbitrary commands on the server hosting the BentoML application. The vulnerability is triggered when a serialized object, crafted to execute OS commands upon deserialization, is sent to any valid BentoML endpoint. This issue poses a significant security risk, enabling attackers to compromise the server and potentially gain unauthorized access or control.
CVE-2024-56433 1 Shadow-maint 1 Shadow-utils 2026-04-15 3.6 Low
shadow-utils (aka shadow) 4.4 through 4.17.0 establishes a default /etc/subuid behavior (e.g., uid 100000 through 165535 for the first user account) that can realistically conflict with the uids of users defined on locally administered networks, potentially leading to account takeover, e.g., by leveraging newuidmap for access to an NFS home directory (or same-host resources in the case of remote logins by these local network users). NOTE: it may also be argued that system administrators should not have assigned uids, within local networks, that are within the range that can occur in /etc/subuid.
CVE-2024-5801 2026-04-15 N/A
Enabled IP Forwarding feature in B&R Automation Runtime versions before 6.0.2 may allow remote attack-ers to compromise network security by routing IP-based packets through the host, potentially by-passing firewall, router, or NAC filtering.