| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Epson "EasyMP" software is designed to remotely stream a users computer to supporting projectors.These devices are authenticated using a unique 4-digit code, displayed on-screen - ensuring only those who can view it are streaming.In addition to the password, each projector has a hardcoded "backdoor" code (2270), which authenticates to all devices. |
| The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue. |
| D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session. |
| A hard-coded password of tecn0visi0n for the dlxuser account in TecnoVISION DLX Spot Player4 (all known versions) allows remote attackers to log in via SSH and escalate privileges to root access with the same credentials. |
| An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |
| Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software. |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module. |