Search Results (2330 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2025-2355 2026-04-15 3.3 Low
A vulnerability was found in BlackVue App 3.65 on Android and classified as problematic. Affected by this issue is some unknown functionality of the component API Endpoint Handler. The manipulation of the argument BCS_TOKEN/SECRET_KEY leads to unprotected storage of credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-27147 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 7.4 High
The Toshiba printers are vulnerable to a Local Privilege Escalation vulnerability. An attacker can remotely compromise any Toshiba printer. As for the affected products/models/versions, see the reference URL.
CVE-2024-12650 2026-04-15 5.4 Medium
An attacker with low privileges can manipulate the requested memory size, causing the application to use an invalid memory area. This could lead to a crash of the application but it does not affected other applications.
CVE-2023-47480 1 Puredata 1 Puredata 2026-04-15 8.4 High
An issue in Pure Data 0.54-0 and fixed in 0.54-1 allows a local attacker to escalate privileges via the set*id () function.
CVE-2023-40067 1 Intel 1 Converged Security Management Engine Firmware 2026-04-15 5.7 Medium
Unchecked return value in firmware for some Intel(R) CSME may allow an unauthenticated user to potentially enable escalation of privilege via physical access.
CVE-2025-4395 2026-04-15 6.8 Medium
Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
CVE-2023-49963 2026-04-15 8.8 High
DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control.
CVE-2024-45283 2026-04-15 6 Medium
SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data.
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-46809 1 Suse 2 Manager, Manager Server 2026-04-15 5.7 Medium
A Plaintext Storage of a Password vulnerability in SUSE exposes the credentials for the HTTP proxy in the log files. This issue affects Container suse/manager/4.3/proxy-httpd:4.3.16.9.67.1: from ? before 4.3.33-150400.3.55.2; Container suse/manager/5.0/x86_64/proxy-httpd:5.0.5.7.23.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Proxy-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Proxy Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2.
CVE-2024-8767 1 Acronis 3 Backup Extension For Plesk, Backup Plugin For Cpanel \& Whm, Backup Plugin For Directadmin 2026-04-15 N/A
Sensitive data disclosure and manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Backup plugin for cPanel & WHM (Linux) before build 619, Acronis Backup extension for Plesk (Linux) before build 555, Acronis Backup plugin for DirectAdmin (Linux) before build 147.
CVE-2025-14126 1 Tozed 2 Zlt M30s, Zlt M30s Pro 2026-04-15 8.8 High
A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-51552 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 6 Medium
Weak password storage vulnerabilities exist in ASPECT if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-1480 1 Unitronics 5 Vision120, Vision230, Vision280 and 2 more 2026-04-15 7.5 High
Unitronics Vision Standard line of controllers allow the Information Mode password to be retrieved without authentication.
CVE-2025-9055 3 Axis, Axis Communications Ab, Linux 3 Axis Os, Axis Os, Linux 2026-04-15 6.4 Medium
The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account.
CVE-2022-38695 2026-04-15 7.8 High
In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).