| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Airtable.js is the JavaScript client for Airtable. Prior to version 0.11.6, Airtable.js had a misconfigured build script in its source package. When the build script is run, it would bundle environment variables into the build target of a transpiled bundle. Specifically, the AIRTABLE_API_KEY and AIRTABLE_ENDPOINT_URL environment variables are inserted during Browserify builds due to being referenced in Airtable.js code. This only affects copies of Airtable.js built from its source, not those installed via npm or yarn. Airtable API keys set in users’ environments via the AIRTABLE_API_KEY environment variable may be bundled into local copies of Airtable.js source code if all of the following conditions are met: 1) the user has cloned the Airtable.js source onto their machine, 2) the user runs the `npm prepare` script, and 3) the user' has the AIRTABLE_API_KEY environment variable set. If these conditions are met, a user’s local build of Airtable.js would be modified to include the value of the AIRTABLE_API_KEY environment variable, which could then be accidentally shipped in the bundled code. Users who do not meet all three of these conditions are not impacted by this issue. Users should upgrade to Airtable.js version 0.11.6 or higher; or, as a workaround unset the AIRTABLE_API_KEY environment variable in their shell and/or remove it from your .bashrc, .zshrc, or other shell configuration files. Users should also regenerate any Airtable API keys they use, as the keysy may be present in bundled code. |
| Insufficiently Protected Credentials vulnerability in the remote backups application on Western Digital My Cloud devices that could allow an attacker who has gained access to a relevant endpoint to use that information to access protected data. This issue affects: Western Digital My Cloud My Cloud versions prior to 5.25.124 on Linux. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.
This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. |
| Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. |
| Insufficient protection of password storage in system firmware for Intel NUC7i3BNK, NUC7i3BNH, NUC7i5BNK, NUC7i5BNH, NUC7i7BNH versions BN0049 and below allows local attackers to bypass Administrator and User passwords via access to password storage. |
| VMware vCenter Server (6.5 prior to 6.5 U1) contains an information disclosure vulnerability. This issue may allow plaintext credentials to be obtained when using the vCenter Server Appliance file-based backup feature. |
| An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application. |
| Wireless IP Camera (P2P) WIFICAM devices have an "Apple Production IOS Push Services" private RSA key and certificate stored in /system/www/pem/ck.pem inside the firmware, which allows attackers to obtain sensitive information. |
| An Insufficiently Protected Credentials issue was discovered in LOYTEC LVIS-3ME versions prior to 6.2.0. The application does not sufficiently protect sensitive information from unauthorized access. |
| A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. |
| A vulnerability in the Virtual Network Function Manager's (VNFM) logging function of Cisco Ultra Services Platform could allow an authenticated, local attacker to view sensitive data (cleartext credentials) on an affected system. More Information: CSCvd29355. Known Affected Releases: 21.0.v0.65839. |
| Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors. |
| On Wireless IP Camera (P2P) WIFICAM devices, access to .ini files (containing credentials) is not correctly checked. An attacker can bypass authentication by providing an empty loginuse parameter and an empty loginpas parameter in the URI. |
| D-Link DIR-130 firmware version 1.23 and DIR-330 firmware version 1.12 do not sufficiently protect administrator credentials. The tools_admin.asp page discloses the administrator password in base64 encoding in the returned web page. A remote attacker with access to this page (potentially through a authentication bypass such as CVE-2017-3191) may obtain administrator credentials for the device. |
| The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements. |
| A design flaw in authentication in Synology Photo Station 6.0-2528 through 6.7.1-3419 allows local users to obtain credentials via cmdline. Synology Photo Station employs the synophoto_dsm_user program to authenticate username and password by "synophoto_dsm_user --auth USERNAME PASSWORD", and local users are able to obtain credentials by sniffing "/proc/*/cmdline". |
| register.ghp in EFS Software Easy Chat Server versions 2.0 to 3.1 allows remote attackers to discover passwords by sending the username parameter in conjunction with an empty password parameter, and reading the HTML source code of the response. |
| An issue was discovered on Mimosa Client Radios before 2.2.3. In the device's web interface, there is a page that allows an attacker to use an unsanitized GET parameter to download files from the device as the root user. The attacker can download any file from the device's filesystem. This can be used to view unsalted, MD5-hashed administrator passwords, which can then be cracked, giving the attacker full admin access to the device's web interface. This vulnerability can also be used to view the plaintext pre-shared key (PSK) for encrypted wireless connections, or to view the device's serial number (which allows an attacker to factory reset the device). |
| An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password. |
| PostgreSQL versions before 9.2.22, 9.3.18, 9.4.13, 9.5.8 and 9.6.4 are vulnerable to authorization flaw allowing remote authenticated attackers to retrieve passwords from the user mappings defined by the foreign server owners without actually having the privileges to do so. |