| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Due to reliance on a trivial substitution cipher, sent in cleartext, and the reliance on a default password when the user does not set a password, the Remote Mouse Server by Emote Interactive can be abused by attackers to inject OS commands over theproduct's custom control protocol. A Metasploit module was written and tested against version 4.110, the current version when this CVE was reserved. |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for .NET may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for .NET to version 3.2.0 or later. |
| Missing cryptographic key commitment in the AWS SDK for PHP may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for PHP to version 3.368.0 or later |
| Missing cryptographic key commitment in the AWS SDK for Ruby may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for Ruby to version 1.208.0 or later. |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for Java may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for Java to version 4.0.0 or later. |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for Go may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for Go to version 4.0 or later. |
| Successful exploitation of this vulnerability could allow an attacker (who needs to have Admin access privileges) to read hardcoded AES passphrase, which may be used for decryption of certain data within backup files of 2N Access Commander version 1.14 and older.
2N has released an updated version 3.3 of 2N Access Commander, where this vulnerability is mitigated. It is recommended that all customers update 2N Access Commander to the latest version. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS).
This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports. |
| The device is observed to accept deprecated TLS protocols, increasing the risk of cryptographic weaknesses. |
| Missing cryptographic key commitment in the AWS SDK for C++ may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for C++ to version 1.11.712 or later |
| SmartOS, as used in Triton Data Center and other products, has static host SSH keys in the 60f76fd2-143f-4f57-819b-1ae32684e81b image (a Debian 12 LX zone image from 2024-07-26). |
| A vulnerability in the SageMaker Workflow component of aws/sagemaker-python-sdk allows for the possibility of MD5 hash collisions in all versions. This can lead to workflows being inadvertently replaced due to the reuse of results from different configurations that produce the same MD5 hash. This issue can cause integrity problems within the pipeline, potentially leading to erroneous processing outcomes. |
| A private key disclosure vulnerability exists in ZTE's ZXMP M721 product. A low-privileged user can bypass authorization checks to view the device's communication private key, resulting in key exposure and impacting communication security. |
| VyOS 1.3 through 1.5 (fixed in 1.4.2) or any Debian-based system using dropbear in combination with live-build has the same Dropbear private host keys across different installations. Thus, an attacker can conduct active man-in-the-middle attacks against SSH connections if Dropbear is enabled as the SSH daemon. I n VyOS, this is not the default configuration for the system SSH daemon, but is for the console service. To mitigate this, one can run "rm -f /etc/dropbear/*key*" and/or "rm -f /etc/dropbear-initramfs/*key*" and then dropbearkey -t rsa -s 4096 -f /etc/dropbear_rsa_host_key and reload the service or reboot the system before using Dropbear as the SSH daemon (this clears out all keys mistakenly built into the release image) or update to the latest version of VyOS 1.4 or 1.5. Note that this vulnerability is not unique to VyOS and may appear in any Debian-based Linux distribution that uses Dropbear in combination with live-build, which has a safeguard against this behavior in OpenSSH but no equivalent one for Dropbear. |
| The use of a broken or risky cryptographic algorithm was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software uses an insecure implementation of the RSA encryption algorithm. |
| php-censor v2.1.4 and fixed in v.2.1.5 was discovered to utilize a weak hashing algorithm for its remember_key value. This allows attackers to bruteforce to bruteforce the remember_key value to gain access to accounts that have checked "remember me" when logging in. |
| A vulnerability was found in gooaclok819 sublinkX up to 1.8. It has been declared as problematic. This vulnerability affects unknown code of the file middlewares/jwt.go. The manipulation with the input sublink leads to use of hard-coded cryptographic key
. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 1.9 is able to address this issue. The patch is identified as 778d26aef723daa58df98c8060c43f5bf5d1b10b. It is recommended to upgrade the affected component. |
| hpke-js is a Hybrid Public Key Encryption (HPKE) module built on top of Web Cryptography API. Prior to version 1.7.5, the public SenderContext Seal() API has a race condition which allows for the same AEAD nonce to be re-used for multiple Seal() calls. This can lead to complete loss of Confidentiality and Integrity of the produced messages. This issue has been patched in version 1.7.5. |
| A flaw was found in GnuTLS. The Minerva attack is a cryptographic vulnerability that exploits deterministic behavior in systems like GnuTLS, leading to side-channel leaks. In specific scenarios, such as when using the GNUTLS_PRIVKEY_FLAG_REPRODUCIBLE flag, it can result in a noticeable step in nonce size from 513 to 512 bits, exposing a potential timing side-channel. |
| Inadequate encryption strength for some Edge Orchestrator software for Intel(R) Tiberâ„¢ Edge Platform may allow an authenticated user to potentially enable escalation of privilege via adjacent access. |