| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The NASA’s Interplanetary Overlay Network (ION) is an implementation of Delay/Disruption Tolerant Networking (DTN). A segmentation fault occurs with ION-DTN BPv7 software version 4.1.3 when a bundle with a Destination Endpoint ID (EID) set to dtn:none is received. This causes the node to become unresponsive to incoming bundles, leading to a Denial of Service (DoS) condition. This vulnerability is fixed in 4.1.3s. |
| Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
The affected models are out of support; replacing the device is recommended. |
| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |
| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. |
| FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC). |
| The RupsMon.exe service executable in UPSilon 2000 has insecure permissions, allowing the 'Everyone' group Full Control. A local attacker can replace the executable with a malicious binary to execute code with SYSTEM privileges or simply change the config path of the service to a command; starting and stopping the service to immediately achieve code execution and privilege escalation |
| Deserialization of Untrusted Data vulnerability in Topal Solutions AG Topal Finanzbuchhaltung on Windows allows Remote Code Execution.This issue affects at least Topal Finanzbuchhaltung: 10.1.5.20 and is fixed in version 11.2.12.00 |
| The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product
features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz.
This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365).
CVE-2025-4009 covers the command injection in feature-transfer-import.php
CVE-2025-10364 covers the command injection in feature-transfer-export.php
Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices.
This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others. |
| The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product
features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz.
This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365).
Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices.
This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others. |
| SQL injection vulnerability in DIAL's CentrosNet v2.64. Allows an attacker to retrieve, create, update, and delete databases by sending POST and GET requests with the 'ultralogin' parameter in '/centrosnet/ultralogin.php'. |
| The affected Raisecom devices allow SSH sessions to be established without completing user authentication. This could allow attackers to gain shell access without valid credentials. |
| CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication. |
| The Survision LPR Camera system does not enforce password protection by default. This allows access to the configuration wizard immediately without a login prompt or credentials check. |
| Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard
administrative means. An attacker with network access to the device can
gain administrative access to the system. |
| The Ready_ application's Profile section allows users to upload files of any type and extension without restriction. If the server is misconfigured, as it was by default when installed at the turn of 2021 and 2022, it can result in Remote Code Execution. Refer to the Required Configuration for Exposure section for more information. |
| Improper neutralization of input provided by a low-privileged user into a file search functionality in Ready_'s Invoices module allows for SQL Injection attacks. |
| rfc3161-client is a Python library implementing the Time-Stamp Protocol (TSP) described in RFC 3161. Prior to version 1.0.3, there is a flaw in the timestamp response signature verification logic. In particular, chain verification is performed against the TSR's embedded certificates up to the trusted root(s), but fails to verify the TSR's own signature against the timestamping leaf certificates. Consequently, vulnerable versions perform insufficient signature validation to properly consider a TSR verified, as the attacker can introduce any TSR signature so long as the embedded leaf chains up to some root TSA. This issue has been patched in version 1.0.3. There is no workaround for this issue. |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |