| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| An unauthenticated command injection vulnerability exists in stamparm/maltrail (Maltrail) versions <=0.54. A remote attacker can execute arbitrary operating system commands via the username parameter in a POST request to the /login endpoint. This occurs due to unsafe handling of user-supplied input passed to subprocess.check_output() in core/http.py, allowing injection of shell metacharacters. Exploitation does not require authentication and commands are executed with the privileges of the Maltrail process. |
| Python Social Auth is a social authentication/registration mechanism. Prior to version 5.4.1, due to default case-insensitive collation in MySQL or MariaDB databases, third-party authentication user IDs are not case-sensitive and could cause different IDs to match. This issue has been addressed by a fix released in version 5.4.1. An immediate workaround would be to change collation of the affected field. |
| An Incorrect Implementation of Authentication Algorithm and Exposure of Data Element to Wrong Ses-sion vulnerability in the session handling used in B&R APROL <4.4-00P5 may allow an authenticated network attacker to take over a currently active user session without login credentials. |
| Sensitive information disclosure due to missing authentication. The following products are affected: Acronis True Image (macOS) before build 41725, Acronis True Image (Windows) before build 41736, Acronis True Image OEM (macOS) before build 42571, Acronis True Image OEM (Windows) before build 42575. |
| Server-Side Access Control Bypass vulnerability in WombatDialer before 25.02 could allow unauthorized users to potentially call certain services without the necessary access level. This issue is limited to services used by the client (not the general-use JSON services) and requires reverse engineering of the proprietary serialization protocol, making it difficult to exploit. |
| Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability in the ExportConfig REST API that allows attackers to download sensitive configuration files. Attackers can exploit the getConfigExportFile.cgi endpoint to retrieve system configurations, potentially enabling authentication bypass and privilege escalation. |
| FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication. |
| SAP NetWeaver Enterprise Portal OBN does not perform proper authentication check for a particular configuration setting. As result, a non-authenticated user can set it to an undesired value causing low impact on integrity. There is no impact on confidentiality or availability of the application. |
| PutongOJ is online judging software. Prior to version 2.1.0-beta.1, unprivileged users can escalate privileges by constructing requests. This can lead to unauthorized access, enabling users to perform admin-level operations, potentially compromising sensitive data and system integrity. This problem has been fixed in v2.1.0.beta.1. As a workaround, one may apply the patch from commit `211dfe9` manually. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| It is possible to bypass the clipping level of authentication attempts in SolaX Cloud through the use of the 'Forgot Password' functionality as an oracle. |
| A Missing Authentication for Critical Function issue affecting the HTTP service running on the DJI Mavic Mini 3 Pro on the standard port 80 could allow an attacker to enumerate and download videos and pictures saved on the drone internal or external memory without requiring any kind of authentication. |
| A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |
| The SAP Internet Communication Framework does not conduct any authentication checks for features that need user identification allowing an attacker to reuse authorization tokens, violating secure authentication practices causing low impact on Confidentiality, Integrity and Availability of the application. |
| Missing authentication for critical function vulnerability exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote unauthenticated attacker may update or downgrade the firmware on the device. |
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. |