| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| Horner Automation’s RCC 972 with firmware version 15.40 has a static encryption key on the device. This could allow an attacker to perform unauthorized changes to the device, remotely execute arbitrary code, or cause a denial-of-service condition. |
| Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
|
| An information disclosure vulnerability exists due to the hardcoded TLS key of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information. An attacker can perform a man-in-the-middle attack to trigger this vulnerability. |
| An information disclosure vulnerability exists in the router configuration export functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to increased privileges. An attacker can send an HTTP request to trigger this vulnerability. |
| lib/util/miq-password.rb in Red Hat CloudForms 3.0 Management Engine (CFME) before 5.2.4.2 uses a hard-coded salt, which makes it easier for remote attackers to guess passwords via a brute force attack. |
| Zoom Rooms for macOS clients before version 5.11.4 contain an insecure key generation mechanism. The encryption key used for IPC between the Zoom Rooms daemon service and the Zoom Rooms client was generated using parameters that could be obtained by a local low-privileged application. That key can then be used to interact with the daemon service to execute privileged functions and cause a local denial of service. |
| A vulnerability was found in FastCMS 0.1.5. It has been declared as critical. This vulnerability affects unknown code of the component JWT Handler. The manipulation leads to use of hard-coded cryptographic key
. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. |
| Nexpose and InsightVM virtual appliances downloaded between April 5th, 2017 and May 3rd, 2017 contain identical SSH host keys. Normally, a unique SSH host key should be generated the first time a virtual appliance boots. |
|
Dell SupportAssist for Home PCs (version 3.11.4 and prior) and SupportAssist for Business PCs (version 3.2.0 and prior) contain cryptographic weakness vulnerability. An authenticated non-admin user could potentially exploit the issue and obtain sensitive information.
|
| An authentication bypass vulnerability exists in the requestHandlers.js verifyToken functionality of Milesight VPN v2.0.2. A specially-crafted network request can lead to authentication bypass. An attacker can send a network request to trigger this vulnerability. |
| MGT-COMMERCE CloudPanel ships with a static SSL certificate to encrypt communications to the administrative interface, shared across every installation of CloudPanel. This behavior was observed in version 2.2.0. There has been no indication from the vendor this has been addressed in version 2.2.1. |
| SolarWinds Web Help Desk was found to have a hardcoded cryptographic key that could allow the disclosure of sensitive information from the software. |
| PanIndex is a network disk directory index. In Panindex prior to version 3.1.3, a hard-coded JWT key `PanIndex` is used. An attacker can use the hard-coded JWT key to sign JWT token and perform any actions as a user with admin privileges. Version 3.1.3 has a patch for the issue. As a workaround, one may change the JWT key in the source code before compiling the project.
|
| A hardcoded key in Ivanti Connect Secure before version 22.7R2.3 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data. |
| Code Dx versions prior to 2023.4.2 are vulnerable to user impersonation attack where a malicious actor is able to gain access to another user's account by crafting a custom "Remember Me" token. This is possible due to the use of a hard-coded cipher which was used when generating the token. A malicious actor who creates this token can supply it to a separate Code Dx system, provided they know the username they want to impersonate, and impersonate the user. Score 6.7 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C
|
| A use of hard-coded cryptographic key in Fortinet FortiSwitch version 7.4.0 and 7.2.0 through 7.2.5 and 7.0.0 through 7.0.7 and 6.4.0 through 6.4.13 and 6.2.0 through 6.2.7 and 6.0.0 through 6.0.7 allows attacker to execute unauthorized code or commands via crafted requests. |
| AXIS OS 11.0.X - 11.3.x use a static RSA key in legacy LUA-components to protect Axis-specific source code. The static RSA key is not used in any other secure communication nor can it be used to compromise the device or any customer data. |
|
Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies. Hard-coded cryptographic key may lead to privilege escalation. This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited.
|